Subterranean Heating and Cooling System (for solar heated greenhouses)
Underground Air Circulation Tubing (for a SHCS - 4" thin wall, corrugated, perforated polyethylene drainage line - commonly called ADS
or Advanced Drainage System)
To
put it in a nutshell, hot moist daytime air of the greenhouse is
circulated through underground tubing and then back into the
greenhouse cooled and dryer. The result is a greenhouse cooled in the day by soil that is
heating up, and a nighttime greenhouse that is much, much warmer because of the high soil temperatures. It makes perfect sense,
but we never discovered how great it would work until we did it in a number of
projects and
noticed that because the air is so moist and dropped in
temperature, that the phenomenon of dewpoint occurs. Because it reaches dewpoint
it "acts" as a refrigerator using the phase change of water rather than
the phase change of freon.
First up, how does one cool air? What is actually going on? From what I can see here,
it's entirely based on the fact that greenhouses are our own living, breathing
mini-micro rain forest that we custom tune to time shift the daily and the
seasonal extremes. In other
words, we are looking at the perfect model of a solar powered cooling machine -
a mini rain forest we control - that can absorb the daily solar gains above
ground, and induce them into cooling 'afternoon rains' underground.
In the solar greenhouse, the plants
and soil give up their water as vapor, and to do that they must have
some heat (BTU's - British Thermal Units) to do it. Some BTU's are used for
directly evaporating water from the soil and plant surfaces, some BTU's
for powering plant transpiration (the plants breath in the air, then breath it
out as moister air - just as we do - chemical photosynthesis
AND physical transpiration create vapor from solar gain - both
processes consume BTU's). So, we have this air that is using up most of
the BTU's from the sun by creating vapor. If we don't remove those BTU's from
the air, then we will have to remove the air from the greenhouse. Old school says remove the air.
Now, if its 90 degs F outside, and your house is hovering around 100/110, old school logic
doesn't pay off much - the most cooling that is physically possible is
to get it is the 90 degree temperature of the air you replace it with. Not much good, considering that if
you're trying to cool a 100 degree greenhouse with 90 degree air, it will take huge
energy sucking fans if it's enclosed or you have to build a house that is virtually open to
the outside. Anyway, maybe that is what has worked best for cooling. That would depend on whether a totally open greenhouse
works for your production plans or not. If it doesn't then we are
looking at huge fans if we go old school. Throw in the added expense of some
fan$y evaporative cooling pads, and you might just squeak by.
So lets look at "new school"
approach.
First, the golden rule when your are moving heat through something. If there is no
difference in temperatures within the model that you can take advantage of, there will be no heat
movement. Heat only moves about if there is a "hot going to cold" pathway. In
other words, to move
heat you need to have a heat "sink". Old school knew that, so everybody
started cramming cold massive things (heat 'sinks') into the space, using up expensive floor
space in the process - trombe walls, concrete floors, rock storage,
water barrels, etc, etc... with very little consideration of the fact
that most houses are sitting on literally tons of heat sink in the form
of the 3 feet of subsoil under and IN the building already.
Problem was, how to interface the sub-soil as an effective heat sink.
One method is embodied in
the construction details of the SHCS - the subject of this consideration. When the initial thought to use
the soil as a heat sink was floating around in the industry, most engineering types were thinking of conducting the heat of
just the air into the
soil. They were just expanding on the original concept of water
barrels, rocks and mass in the space. 'let's just let them heat up in the sun,
or by us moving hot air around them and that would suck up the heat...'
So we have this thing called
conduction as the old school starting point. Choose a good heat sink, and move
hot air to it, and therefore conduct the heat to it somehow... Now, what was missing in this picture was that
we are not looking at the ACTUAL heat gain engine in a hot, moist, for real
greenhouse - the vapor cycle.
The air itself doesn't actually absorb many BTU's, it is the water heating up and
vaporizing, and the BTU's to do that are absorbed into the system
as "heat of evaporation" contained within the actual vapor component of the
air. So, looking at hot air conduction transfers we're
missing the real point. There was some use in including conductive
transfers, but not enough to ever justify taking up space in the
greenhouse. What we actually need to do here is get back those BTU's
used in the "heat of evaporation".
Now, the interesting point here is
that physics law tells us that it takes 500 times more BTU's to
vaporize water then it does to raise it's temperature one deg F. And it
tells us that if you condense water out of the air, you are getting
back the "heat of evaporation" as "warm water". So we are looking at a
potential cycle of heat transfer that is 500 times more efficient than
conduction transfers alone! Of course, that number is never actually
met in a system that can be practically set up - that's just the 'theory', but even if there is 10
times more heat transfer, it's still money in the bank. So.... after
that bit of long winded pre-amble, let's move on.
If we are to zero in on using
the "heat of evaporation" gains and take advantage of them,
we have to somehow condense the water out of the greenhouse air. So we get into another
concept - dewpoint. When water vapor reaches dewpoint, it condenses into a liquid,
and in the process releases all the energy it took to cross over the evaporation
barrier and become liquid water again.
So what does it take for the air to reach dewpoint? It must be cooled to the
dewpoint temperature. To do that we
need to introduce an opportunity for conductive heat losses that lower the
temperature of the air to dewpoint, the point at which the air saturates, goes to the highest
level of humidity it can physically maintain. Then we take it just 1
deg further. Bam! the vapor condenses, and the heat of evaporation
is released, and it rains. Now look at this - the dewpoint is
dependent on the humidity of the air AND it's temperature. That's why we call it
'Relative Humidity - RH'. The higher
the humidity, the less conductive loss is needed to get to dewpoint - i.e. the
higher the dewpoint temperature. That sounds
like a greenhouse full of plants doesn't it - hot and steamy - meaning the conductive loss we need
in a greenhouse to bring the air to dewpoint is minimal.
Now for some rules of
thumb - dropping normal ambient air temperature by 30 deg F will often bring it to
dewpoint (the cold sweaty glass of water experience.) In a greenhouse that is
much higher in humidity, that figure likely drops to 20 or 10 or even as little
as 5 deg F. So how do you
drop the temperature of vapor saturated greenhouse air by that much.?
Well you are going to need something at least a few degree's lower than the
dewpoint temperature. And what is the most logical source of this kind of heat
sink? Of course it's the soil - soil seldom gets above 60 deg's F on its
own. If it's at 60 deg F., then 90 deg F. saturated air should be able
to get to dewpoint without too much trouble. So that is the "mark" to
work with - max soil temp of 60 - 70 deg F., saturated air temps in the
80 to 90 deg. F. range. Sounds like a normal working greenhouse to me!
Now, how do we get all that air intimate with the soil so that conductive loss
does bring all the air in the greenhouse to dewpoint?
Enter the SHCS. All of the UACT installed at close proximity to each other
and laced throughout the sub-soil gives us good intimate contact with the
mass. How much soil
to interface is the next question. So some more physics... It takes one BTU to raise the temp of one pound of water one deg.
F (close to the same for soil
mass). Loose, moist soil weighs in at about 76 lbs/cu.ft.,
so a yard of it is about 2052 lbs. So, it takes about 2000 BTU's to
raise one yard of soil one deg. In other words, for every square yard
of surface, the current SHCS specs (3 layer matrix interfacing with
about 3 feet of soil) can suck up 2000 BTU's or about 222.22 BTU's per
square foot for EACH single degree change. A 20x30 foot greenhouse (600
sqft) would have to absorb 133,332 BTU's before the soil temp raises one
degree! Just in case you need a gauge, a normal household water heater
uses 30k BTU's per hour - this represents the same heat transfer as
you'd see in a gas fired water heater running for about full tilt for 4 1/2 hours. Now,
experience has shown that the soil temp raises at least 20 deg. above
normal in a summers season using the SHCS. That represents 2.67 million BTU's of accumulated heat tied up in the
soil, the equivalent of a hot water heater steadily running full tilt for about
89 hours (. Looking at cooling only, that
translates to 2.67 million BTU's of cooling effect. (not to mention the
obvious perk of having all that water vapor recycled back into the soil as warm
sub-irrigation for the plants!)
If the daily solar gain adds more than 1 deg of change in
the soil temperature, there still could be losses that same night. The important thing
to remember is that EVERY day there is an addition as long as there is a
potential of solar gain but the loss each night is not necessarily as large as
the gains every day. Each day that there is a 1 degree change in the
soil temperature, you have gained this hypothetical amount of BTU's. Every
day that you do that represents money in the bank as cooling benefit, and
each night that the losses are less represents money in the bank as heating
benefit. I believe that these systems can easily do that 1 degree shift in
soil temperature every day
for at least half the year on average. In this example that represents 180
days x133,332 BTU's = 24 Million BTU's of heat transfer. At the end of the summer season you
will be going into the winter with most of those gains stored as elevated soil
temps. For every cold winter day that the sun shines brightly into
the greenhouse, you store enough heat that day to make up for that night's
losses and therefore don't draw on these reserves. You only draw from the
summer's stored gains when the winter sun's gains are less than the night's
losses.
Let's look at some cash flow
statistics for a 600 square foot solar heated greenhouse. In 2004 in Colorado, 1 million
BTU's of Natural Gas
costs about $8.50. For every degree of soil temperature increase, we are
pumping the gas equivalent of $1.13 underground. Do that for 180 days and that
represents $204 in accumulated gains. A single 20F rise in total soil temp represents
$22.60 in Nat Gas
potential energy stored from the sun. This is not an aggregate total though. The energy is
being added and subtracted on a daily basis. The 20F increase is easily
achieved in 3 months, so, taking in account the available gain for the
year, you can be sure that the system has moved around 2 to 3 times that
amount of energy (up to $612 per year in gas heating stored in the
soil) and made it available for night heating and better soil
temperatures. From these numbers, we can see the significance of
raising subsoil temperatures. This is not theory, I regularly see soil
temps elevated 20F in SHCS greenhouses. If you build a simple hoop
double inflated greenhouse for $4/sqft, say a 20x30 600sqft GH ($1500 delivered
for frame and skin), the
gas energy absorbed each year represents almost 1/2 of the cost of the
greenhouse that is being "banked" in the soil as heat you'd otherwise be paying
cash for to get the same high quality growing environment.
So, the numbers so far:
- - keep
the soil temperature and saturated air temperature differential high - in the
20-30 deg F range
- - interface with the subsoil for about 3 feet deep using a 2' OC
horizontal/1' OC vertical UACT matrix
- - move all the air underground 5
times per hour and dump it back into the space AND keep the air speed in the tubing
down to less than 4 feet per sec.
If you can do this,
then you can expect dewpoint, and if you can achieve dewpoint, then the
system pays for itself quickly.
If you just barely get to those kinds of figure's in your design, then you still
benefit - because the soil and the plant roots will warm up from
conductive transfers, a solar interface to the sub-soil remains a huge bonus
even without a perfectly optimized magical vapor phase changer - your plants
will still grow much
faster AND you still get a longer growing season than if you'd done nothing.
Overheating of the soil? Not an issue. Remember, heat only moves from
"hot" to "cold". In order to heat the soil to undesirable temperatures
(>90F.) you'd have to have the air temps in the 110-120F. range.
At which point, it is the air temperatures that will be your problem! But
because of the dynamic we are working with here, the hotter it gets, the more
efficient the phase change action works. Only when the soil reaches a null
point of about 75 deg F does the effectiveness drop off. But that only
happens when there is little need for night heat, so you don't need to store it
anyway... just vent it out for that period anyway.
Venting? Yes, you will have to vent, but only to manage your humidity
and temperatures when they start to go beyond the numbers that work for
a SHCS and the plants. Vent to prevent temp >95/100F. or humidity
>95/100RH. Modulate the venting to keep the humidity and temps
high, but use the SHCS to cool as much as it can before you vent. Too much
premature venting will
dry out the space, impact the performance of an optimized SHCS cycle and stress
the plants.
It should be clear that there
will be control for some portion of the summer. If your summer net gain
period is beyond 3 months and your winter net loss period is less than 3
months, then the system will be performing well for you but you will have very little mid-day late
summer cooling potential. You will have to vent to more to get by. It's
usually not so hot by then, so it's not normally an issue. But, and it is a BIG but, do not fall for the
shortsighted conclusion that the SHCS solves all your heating and cooling
issues. Conventional, controlled and moderate venting will still be
necessary. Besides, we've been discovering that it is the air conditioning effect on the
space AND the soil that is incredibly useful all on it's own. The plants simply thrive
in magical ways because of the warm moist air at the root zone. That is a factor for you to
keep well enough in mind. Of course, with plants in pots or on benches, that effect
is less, but the warmer 'floor' still has value to you as radiant heat affecting
your production positively.
On another tact, say all you want do is cool all year, you have virtually no
heating needs. How about adding UACT outside the perimeter of the greenhouse. Whether the
cost is going to work, I don't know yet, but I've some projects on the go in
New Zealand where we're testing the installation of extra tubing
outside the perimeter of the greenhouse. Once the soil matrix in the
building is up to temp, the circulating air is going to be directed to
the matrix outside, permitting a longer period of the year that cooling
can be achieved with out the daily gains accumulating inside the building. Combine this with careful use of shade compound to
limit gains and using open structured greenhouse design for maximum venting, you could have a
winning combination for super cooling without needing to vent excessively.
So, you're trying to optimizing
for cooling, not heating. [see section just before this one] Any cooling emphasis in the design will, of
course, show up as effecting the heating performance of the space -
that is just the design - transfer the heat as condensate underground
and the space cools, but the soil also heats up. So, that being the
case, I am going to say here, right up front, that this is new
territory for me. My designs have always focused on keeping greenhouses
from freezing. I was a Canuck hobbit in another life after all. It just so happens that the
cooling effect was a critical bonus, but not a design focus. That being
said, we are going to have to step back from the concepts I've focused
on for heating emphasis, and see if there are any factors that are in
the picture that we can dance with that have a cooling emphasis. The first one
is to open the greenhouse completely. There is no use fighting the heat
gain if effective design can allow you to easily open and close your house,
preferably automatically. The second thing you could do is add a small and simple
automatic misting
system to absorb every little wee bit of the solar energy - especially when the
greenhouse is completely closed. The
extra humidity can be vented or condensed as stored heat with the SHCS.
Some are now experimenting with extra Underground Air Circulation
Tubing (UACT) outside the perimeter of the GH, installed and used only
when pure cooling is required. That way they do not have all of their heat sink
(and heat storage) inside the GH.
The ultimate answer for
enclosed greenhouses looking for cooling efficiencies is to control the
glazing exposures. By limiting the summer light only to strong enough
levels for growing, most of the heat gain can be avoided. This is being
accomplished with:
- painted on shade compounds
- shade cloth
- planting arrangements that
shade the house deciduously in the summer
- mechanical shutters
- adjustable parabolic light
accumulators
- bubble filled double skinned
glazing
For extra cooling effect, combine interior shade cloth with an automatic mist
cooling system. Be sure to direct the mist cooling to the zone above the
shade cloth and try to vent directly from this zone as well. Think of it
as cooling clouds passing by the canopy of the forest below.
You need to move all the air in
the greenhouse through the UACT at least 5 times an hour.
Measure your space, calculate
the total volume (length times width times height), and multiply that
number by 5. That gives you the total volume of air your fan has to
move every hour. Divide that number by 60 to get the volume of air to
move in a minute. That is the standard measurement used to size any fan and your
fan in particular - Cubit Feet per Minute - or cfm... or you can divide the total
volume by 12 to get the same number because you are also moving all the
air underground once every 12 minutes. When you look at the performance
chart for the fan you have in mind, it will indicate the cfm at the
different air pressures it can generate. Choose the second highest cfm figure in
the chart, it indicates the performance if generating only a wee bit of back
pressure. That should be what the system will be like if built as we design
them.
We recommend using 'in-line' duct booster fans exclusively now. The common
low volume 'squirrel cage' fans we used to specify used shaded pole motors,
different than straight in-line fans. It turned out that when you close
the vents on a tight house with the SHCS running, that the squirrel cage blowers
style fans feed air pressure back onto themselves from the exhaust outlets of
the SHCS. In the process, the oversped their normal running speed and by
design, also drew more current. The extra current resulted in high motor
temperatures in an already high temperature environment and we were getting fast
motor failtures. If you happen to be using a direct drive squirrel cage blower with a shaded pole
motor, you should have a qualified electrician test the current draw of
the fan with all the vents, windows and doors closed. Operating this
way, the fan is essentially back pressuring itself and will tend to
overspeed. With shaded pole motors, this can lead to over drawing of
current. You or your electrician can control excessive current draw by restricting the intake on the blower cage
till it is just below the name plate rating on the motor. If this tuning
procedure is not performed, you could burn out your blower motor
prematurely.
The
system works by moving a lot of air underground at relatively low
speeds inside relatively small tubing. Contact time and surface area is the
secret. It doesn't matter that you can move a lot of air with bigger
fans and bigger pipe. The consumer 'more is better concept' does not apply here
at all. It is the amount of air that has long contact times with
the soil that works. Experience has shown that when you do
the numbers, small fans reach that limit easily, bigger fans are never needed. It
relates to just how much tubing can you practically cram into one barrel plenum
or culvert plenum. Remember, all the air is circulated at VERY slow speeds through
MANY short tubes. The end result is that a lot of air gets moved but
not the kinds of movements that are required for your typical fan powered
household ventilation systems. We are talking here of only moving the volume of
the greenhouse underground once every 10 to 12 minutes with virtually no back
pressure because the speeds are so low. Larger fans
simply don't work out well. A 750 cfm fan is just about all the air one
plenum can handle if it is completely crammed with tubing - works out
to about 10 cfm for each tube. With a bigger fan the tubing air
velocity gets so high the air wouldn't be in contact with the soil long
enough to go to dewpoint.
The only practical way to use bigger fans for massive greenhouse projects
is to use Rock Beds and no UACT at all.... Those kinds of designs are just now
being considered by a few engineers, builders and architects. Hopefully
I will be able to share the specifications soon for managing such
designs. To date, we've designed systems for managing 60,000 square foot
greenhouses in the west using rock beds only. They are working out with
5,000 cfm fans... but I feel we can do it by using the existing ventilation
fans already standard practice for venting in the west. I'd like to see
my designs for using the existing fans to drive the venting when needed, but
also cycle them in one at a time to run the SHCS when it's appropriate.
It's all just a matte of placing them properly and using damper control to
direct the air into and through the house or under and then back into the
house. Email me if you are interested in more up front on the progress
with these kinds of considerations.
Thermodynamic losses would seem to point to entirely insulating the
bottom and around the sides of the SHCS soil zone. However, the
practical costs of doing so may not be warranted.
Insulating under the SHCS soil
zone would give some more control of the heat entrained in the soil
after a summer season of charging it up. Insulation around all of the soil
mass would slow down the losses to the deeper subterranean soil. The
heat loss to that zone would be a factor when the SHCS soil temperature
zone was getting higher than the ambient temperature below it and on the perimeter
at the sides. But keeping in mind that for the movement of heat to be significant, the
temperature differential has to be large as well or the energy doesn't move. The soil temperature in a typical Western Zone 4 SHCS system
will not get much higher than 75 degrees and the ambient soil under the
tubing zone is typically 55 deg F. Therefore I'd say that the migration
below the SHCS zone will be minimal - there is only a 20 deg F.
differential to drive the process through solid mass. However, the sides of the soil mass
can have upwards of 80 to 90 degrees differential! Therefore the likely place
to use insulation to best advantage is the sides. Using it under the
soil mass would do something, about 1/4 the effect of doing the sides, but
typically 6 times more money to accomplish - that cash would be best spent on
insulating the sides only. As always, the biggest exposures - the glazing,
foundations and
walls - should get your attention and capital investment for minimizing heat
loss. Use double
skinned glazing and standard wall and foundation insulating methods to
control your looses there. And watch your construction detailing... an
air-tight greenhouse is a winner greenhouse.
The depth question.... I am
always reminded that telling folks what it should be in their specific
case seldom comes to advantage considering the ease of
misinterpretation that's so prevalent in email. Perhaps I would be
better to describe what is required first, then see what the final
verdict is after we have the tubing drawn into a design. After all, the design must
work, and the numbers are only guidelines.
We are going to try to put in
three layers of tubing. First, we have to start by keeping the top
layer of tubing free of hindrance from the gardener's activity -
measure your pitch fork and garden tools and make sure any planter
located tubes are safely buried below that depth. Secondly, the purpose
of the tubes is to chill the humid greenhouse air to dewpoint - so keep
them surrounded with enough thermal mass so that they are likely to be
cool all day. That means the depth of the top pipe depends also on the
density of the soil. Peaty lighter soil would have to be deeper as it can heat
up quickly from the system and the sun - for clay sandy soils, the pipe
could be higher. Our experience shows that heavier subsoils continue to
act as good heat sinks if the tubing has 6" of subsoil above it (8" OC
from the surface) You should go deeper if your soil mass is lower. Then
there is the relative distance between the tubing in the soil matrix...
That too can be affected by the soil type, but generally we are getting
good results with normal density subsoil by placing the tubing 1' On
Center (OC) vertically and 2' OC horizontally. If the available
installation zones in the house is insufficient, then you can decrease
the 2' OC horizontal spacing to as low as 1' OC and still maintain your
heat sink cool enough. Increase or decrease those numbers depending on
the relative density of the subsoil (I'd consider road base the densest
soil type that is dig-able, and rich pure organic and peaty the lightest soils.)
Using these guidelines, you can make a good guess at just what the deepest tubing
layer will be.
more on depth....
How deep? It makes sense that we would keep the pipes as close to the surface as
we can but still influence as much tonnage of soil as is practical. A
reasonable depth to influence below the root zone is 2 feet. Therefore,
the deepest we would ever need to go is 3 feet, one foot to stay clear
of the root zone so that gardening tools are not going to make a mess
of the tubing and two feet of subsoil to act as the heat sink. You
could go much more and put in much more pipe to extract much more heat,
but there is a ROI that is a factor. In Zone 4, we've found that 2 feet
of effected subsoil works well enough for our investment in tubing and
other equipment.
The 3 foot deep guideline represents about a ratio of space with the rest of
the greenhouse of about .33 parts soil, 1 part air for a normal average
greenhouse height of say, 9 feet. Lower that height to something like 7
feet, and we have about .43 of a cubic foot of soil for every cubic foot of air
we are trying to influence. The higher the ratio of soil to air, the
better cooling and heat stabilization we can achieve. Picking about 1:3
seems to work just fine for now. We can move the ratio in the right
direction by lowering the roof or putting in more tubing deeper. At some
point we'd run out of growing space or money for more UACT, so for now, it's
1:3 to as low as 1:2.
To install the tubing, I
usually just rent a trencher for half a day, rough cut the trenches to
the projected depth and bring it back. That only takes a half day
rental ($120/day here). Make sure you get a 6" model that can cut as
deep as you want. Then excavate the trenches by hand with trenching shovels and
backfill each layer as it is placed.
If your soil can't be trenched or
is too heavy or useless to use for planting, you can excavate the entire mass and
then backfill it with a better choice for soil. This approach almost
always requires that you have equipment and an operator on site for the
duration (or a neighbour who can come over for many sessions with a
front end loader.) You can then lay in each layer in a pattern that
allows them to be backfilled with the excavating equipment. Plan this
part well - you can't drive on the tubing until it is sufficiently
backfilled. It is best to never drive on top of any of it. Try to
backfill from the edges, reaching in as best you can with your
equipment.
Use underground 18" ADS culverts as as plenums for each fan system - one
at each end of the house or system, exhausting at one end of the culvert, and
blowing air into the opposite end on the culvert for the other end of the
system. You can cut just one hole in a barrel plenum and put it over the
end of the culvert for your exhaust plenum and fan plenum. Then cut holes
for the UACT to fit into the culvert soil-tight. Cut all of your
tubing exactly the same length and lay them into each trench or at each back
fill level as you go along.
The UACT can be below the
surface in the paths and then come up a little higher into the planters if your
plan indicates where they are. The last one I did like this, I put in all the tubing right
to the plenum and under the paths and as deep there as I could manage.
Where they were under planters, I trenched a little higher for the
bottom layer and left the top two layers loose on the surface. Then I
created ferrocement planter walls 24" up from the floor, surrounding
the loose tubing. When the walls were done, I could backfill the
planters with amended subsoil, leaving the second layer of tubes on the
undisturbed grade of the floor. Then with better growing soil, I filled the
planter with the top tubes suspended about the middle depth of the
planter. Take a look here.
If
the existing soil is heavy and has enough aggregate for drainage you
can use it safely. Too much clay content is the worst choose, it will
not allow for proper drainage. Choosing to do an install by excavation
and then backfilling with a different material of choice best suited as
a heat sink, I'd go with "road crush" as your backfill (a mix of all
the grades of aggregate from clay to gravel). It is the best
mineralized material for perennials to benefit from, is very massive,
and if you have no heavy traffic on it and do not compact it, is has
good heat and balanced water holding and drainage performance. We have
done this in the past and been very happy with the results as far as
cost, availability and performance for the SHCS and the deep rooted
perennial plantings. Pea gravel is also a good choose. When backfilling
planting zones, just make sure you use materials suitable for plants
and do make sure the soil has good drainage performance.
This is a misunderstanding, for which I would appreciate your
indicating, if you can recall, where it was you read this section.
Under no circumstances have we suggested to or did fill the pipes with
anything!... I am sure that it is a poorly crafted language issue at
work here. Be assured that your suspicions and concerns are warranted.
Air tubing moves air and indeed is not going to do that if they are
full of aggregate... or anything other than air for that matter.
The
design goal I work with is to develop a three level matrix of tubing
that is 2 foot on center horizontally, and 1 foot on center vertically.
More space between the tubing would mean you'd not be influencing all
the soil in the matrix. Keep in mind that soil conducts heat poorly.
The tubing has to be close together to influence all the soil as a
mass. Spreading it out is OK, but you will not be raising the soil
temperature much. It's a balance - if you go too close, the soil temp
raises too high too quick to be effective in the latter part of the
summer (high soil temperature reduces the cooling effect). If you go
too far apart, the summer gains do not raise the soil temp enough for
winter benefit. Loose matrix leads to a cooling emphasis in the design,
tight designs lead to a heating emphasis in the design. You have to
decide. Zone 4 works best with the three levels - 2'OCH x 1'OCV matrix. Go
here for a free
online calculator for your system.
Here are the numbers we've been designing to for most of our systems in
the western states at Ag
Zone 4:
1. You have size the fans to move all the air
of the greenhouse underground about 5 times an hour (the fans have to
move the entire calculated volume of the greenhouse in cfm every 12 minutes -
divide the entire volume by 12 to get that cfm figure)
2. There has to be enough
individual tubes so that the back pressure on the fan is as close to
zero as is possible. The design goal is to have the air moving down
each tube at a maximum speed of 2 to 4 feet per second. The total time
the air spends underground for each cycle is more important than the
speed. The longer the tube, the higher the speed can be. Slow speeds
are important in small greenhouses with short tubes.
3. The tubing has to interface
with as much of the subsoil fill as is possible. A general layout to
design for is to put in three layers of tubing. Space them 2 feet On
Center horizontally and 1 foot On Center vertically. Note that you need
to adjust this figure according to item 5. below.
4. The individual tube lengths
should all be as close as possible to the same length.
5. The total length of all the
tubing should be approximately 1/3 longer in feet than the total square
footage of the greenhouse (i.e.: 6 feet of tubing for every 4 square
foot of floor space.) If this number is smaller than the initial layout
in 3. above, leave it the same, if larger, add more tubes to get close
to that amount of tubing.
6. Vent only to prevent temp >95/100F. or humidity
>95/100RH. Modulate the venting to keep the humidity and temps
high, use the SHCS to cool (store heat) as much as it can.
Go here for a
free online calculator for your system that is based on this design guide.
Re: soil sock for ADS (Advanced
Drainage System) tubing and other similar perforated corrugated thin
wall poly tubing)
This material is available two
ways: with a sock already on the tubing or the sock as a separate item
that you need to apply yourself. The latter is a real pain, so if you
can, get it already on the tubing.
The sock material is supposed
to be an option available at the tubing supply house. If not in stock
that way at the suppliers, then ask them about a special order for the
sock or tubing with the sock pre-installed.
BTW, you only need the sock if
your soil is VERY dry AND sandy during the install. The SHCS will keep
the soil structure intact by reason of the high levels of condensed
water vapor that it introduces. The key is that when working, the SHCS
will saturate the soil enough to keep it from crumbling through the
perforations. As such, there should be little need for the sock being
used to keep out the soil EXCEPT possibly during installation.
Infiltration of soil and debris
into the tubing through the perforations isn't normally a problem BUT
proper screening at the blower plenum and exhaust bunkers after the
installation is still very, very important. Turns out that the tubing
is perfect breeding for pack rats and such. And they WILL mess up the
system. And don't forget - the tubing arrays must be tuned after
installation and periodically through their lifetime (to be sure,
vermin still find their way in, and occasionally tuning them will
indicate that kind of situation clearly). Each tube should be handling
roughly the same amount of air, any that are using significantly more
should be crushed closed enough to encourage more air movement in the
slower tubes.
The
tubing ends are exits for the conditioned air AND burrow entrances for
every varmint that comes along too. So.... of course, they must be
screened individually or collectively if you use a bunker. No smaller
than 1/4" screen though... and the same for the fan end.
Don't even think about putting in your own holes. There are way too
many
required. Try to find another supplier for the pre-perforated option.
And the perforations are very important to prevent any and ALL
puddling. Puddles could lead to a breeding vector for nasty organisms
that moist soil alone cannot support.
Using 3/4" or larger crushed
clean rock is currently not recommended EXCEPT in the bottom of the
foundation drainage lines to keep the water levels below the bottom of
the deepest air circulation tubing. The current thinking is that using
it to backfill the tubing will limit the most important function - heat
transfer. A crushed rock fill could limit the intimate contact of the
mass to the tubing. The amount of air entrained in rock
fills could also act as insulation as well as prevent it from
entrapping moisture for the use of the plants in the greenhouse.
On the other hand, if you did
use such a material in the trenches, it could be of advantage. Because
the tubing is heavily perforated, the air will be escaping into the
spaces between the stones. If it does that it may cool better and
condense out the moisture better. Currently we don't know if that is a
benefit in the overall performance. It would take a pioneering
experiment, doing some trenches this way and checking the air coming
out those tubes. Comparing the measurements with a control set of
regularly backfilled tubing would tell the tale.
Another option for backfilling is pit run screened to no bigger than 1"
rock. This should infill denser than crushed rock and hold more
water. It is usually the cheapest fill too. However, it is important
that this type of fill not have heavy traffic on it. It does compact to
concrete densities if you are not careful.
Ferrocement is my
recommendation for constructing planter walls. Ahhhh, ferrocement a
mystery for you... no worry, it is an easily shattered mystery. It's
quick, simple, dirt cheap, massive, bombproof and very compact. And
it's a breeding ground for a skill set that simply does away with a lot
of construction problems that the usual farming environment simply
would be much better with. Wooden construction is universally a
solution only to carpenters. Just because you're a hammer doesn't mean
everything has to be a nail... In case you were wondering, I've had a
lot of bad experiences with wooden walls in greenhouses. So far, all
have been disappointing ultimately.
There is a photo tour of the
Distro Greenhouse Construction process of ferrocement walls on the site
(Distro Greenhouse with Ferrocement
Walls.) Check it out. Then do a
Google on ferrocement. Ferrocement is the answer for permanent walls,
benches and such in greenhouses.
Yes, it is possible to talk to
me! And I am thankful for any serious interest in the SHCS for solar
heated greenhouses.
I work in the realm of the SHCS
design in my spare time, intent on spreading the good news of our
success so that more experience from others would help the
understanding of these systems mature in the public domain.
First use the Contacts page for email.
I can be reached via the Forums too.
My spare time is not that
abundant, but if you do need to talk on your nickel, be my guest. When I am available, I can be reached directly at (970) 215-4710.
But sorry, I can really only receive and return calls to established clients of Going Concerns Unlimited.
I
don't normally charge for my time if you call as a existing client. So you will have to get used to me simply
helping you out on the phone for free. It does happen, even in these
daze...
Call me on your nickel, my
schedule. If I am not available, you can leave a message when you will
call again, and I will try to meet your needs. If there are any basic
questions you'd like answered from here, then fire away. I am always
available via email...
Go here for an outline of what I provide.
The basic plans package
includes:
- Custom
Floor Plan Layout with the
locations for the trenches and stacked layers of UACT, plenum, return
air bunkers and any noted fixtures included (please provide dimensioned
sketches to get me started.) This drawing includes the total amount of
UACT and the number of tubes.
- Electrical
Schematic with the blower(s) and
two thermostats laid out for night and day operation (with two speed
fan circuits if that is what is being spec'd.) I will specify the exact
fan and thermostats as part numbers from Grainger.
I include the performance specifications so that you can source the
hardware from your own resources.
- Blower
Plenum elevation and description
so that you can build you own.
- Greenhouse
Side View Elevation above and
below ground to show the typical spacing of the UACT matrix in your
soil.
- Spreadsheet
Schedule of your project's
tubing and fan size calculations. You can see the design goal for the
air speed in the tubes and time spent in each one. You can use this
data to compare with your actual performance after you've built the
system.
As little as $100 up front and I can
put the
necessary time aside to do this work for you. I need some time
discussing your specific details and some dimensioned sketches or
drawings from you of your project. If your project is complex and
involves more
time, I will let you know that before I begin.
My fee Schedule escalates as
commitment of time and energy to a project grows:
- $25/hr for plain ordinary
time discussing details of job we agree to work on together.
- $45/hr for time spent
producing client materials for a job - drawings, schedules, schematics,
making and assembly of parts and products...
- $75/hr plus expenses for
on-site directing of work - doing any of the above plus whatever else
that needs doing; supervision of contractors, managing laborers,
scheduling etc.
For simple tubing layouts I do,
it takes me about 2 hours of drawing time plus an hour of basic
interchange and considerations, fact gathering etc. That comes out to
$115. If the scheme is brain dead simple and straight forward (single
plenum, one house, etc) I am usually satisfied with $100. I have to get
into the project before I know just how much real productive time I can
provide that will truly accelerate things for you (or how much time I
will be spending sorting out my own understanding of it. There's no use
charging someone else for my education if that is clearly all that is
happening...)
Scan and email 'em if you can.
If your scanning software can create black and white gifs or compressed
tiffs, then the resolution would be the best for sketches and drawings.
JPG's are ok too, but not the best for file size/resolution issues. If
you can keep it all below 500k my tired old 49.33k dial up shouldn't
have a problem. You could also take a picture of your sketches and send them
along as digital files.
Otherwise, you can mail them to
me at:
John Cruickshank
5765 Colver Road
Talent OR, 97540
The
perimeter insulation...? Yes, the SHCS does need a thermally isolated
mass of soil under the greenhouse. If you are in Ag Zone 5 or 4 you can
dig a trench and put 24" of 2" thick foam board vertically, or you can
place it backfilled horizontally with a 1/4" per foot slope around the
outside of the building. Either way is ok, and your call. If you are doing a
horizontal install, take a look at the Frost
Protected Shallow Foundation specifications manual for details on how to
do it. Just make
sure you don't use white bead board! It is not the same as "blue board"
(closed cell Extruded Polystyrene Foam) and not designed to work
underground. If you are going to pour a concrete stem wall, you can
trench the foundation location and use the foam boards for the outside
of your forming.
Were you thinking of square galvanized tubing? It is the framing
material of choice if you can locate it. Greenhouse manufacturer's
usually stock it, metal dealers seldom do in retail quantities, but
they might in your area. Talk to your metal fencing dealers, they buy their
round galvanized tubing from the same manufacturers who make the square
tubing. They should be able to look after you in their next factory
load. I use 1 1/2" square 16 gauge and 2" square 14
gauge to great advantage here. That builds a very solid investment and
is a piece of cake to assemble in quite complicated forms with nothing
more than a portable metal cutting bandsaw and a good 1/2" drill and
self drilling #10 or #12 self drilling hex head fasteners. Touch up the cut zones with
galvanized primer and you are good to go for 100 years or more... and
if you have a welder handy, you can go a long way to building the whole
house frame. Take a look at some details on my
last project here.
For
power, one 20 amp GFCI circuit will be enough for a SHCS with a single
fan (maybe less than 2 amps at 110 VAC. Inflation blowers for double
skin films draw approximately 1/2 amp at 110 VAC) That could just be an
underground branch circuit off of an existing panel as long as you have
a disconnect at the greenhouse. But you can install a complete split
phase system if you like, just be sure to run a Neutral conductor out
to power up your other 120 volt devices. If you are considering an
independent photo voltaic solar system, you will need about 240 watts
in panels and charge controller, a 300 watt 110 VAC inverter and a 50
AH battery.
Yes, there is at least two
things you can do that I know will improve performance post construction.
- Use a vapor barrier under
your pathway surfacing. By limiting how much evaporation of moisture
occurs in the pathway at night, you limit the uncontrolled night time migration of heat from
the soil to the air. Uncontrolled losses this way will dissipate heat
unnecessarily. Typical pathway sizes could mean you'd be preserving as
much as 20% of the heat loss from the entire exposed soil surfaces. 6
mil poly sheeting under your paving will stop the vapor migration from
deep below and keep them dryer too. Make sure you perforate the plastic
to allow for water to move on through. You can drill holes in the roll
before installing. You shouldn't need more than one or two holes per
square foot.
- Tune up your UACT. If your
tubing lengths are all different, they will have different amounts of
air moving in them. The shorter tubes will have the least air
resistance and will take more air than the rest. Each tube should take
the same amount of air so that your tubes are all doing the same amount
of heat exchange. You can use a wind speed manometer
to measure each one. By pinching the ends shut on the faster ones, you
can balance the whole system so that each tube is doing all the work it
can do.
And the best way to be sure is before you build!! Use the free SHCS
Design and Payback Calculator
Yes, the air is circulated, with the return air near the exhaust
bunkers close to the ground, scrubbing the plant zone for humidity. In
larger houses, this is not of much use though. The air moves back to
the plenum rising quite high and only slightly turbulent. You will find
that large houses can use circulators to advantage if the ceilings are
high.
In
small houses, the shading effect of a large vertical duct in the middle
is too much of a shadow. We are growing plants aren't we? And we've
found from smoke tests that in small houses (less than 1000 sf with low
ceilings) there is enough of a tumbling and turbulent effect to mix the
hot air enough so that the heat is circulated without raised intakes.
Bigger houses will benefit with raised intakes. Shading and suction
losses at the blower have to be taken into account though.
In higher, larger houses, high intakes are recommended. Costs sometimes
need adjustment in very high and large greenhouses (over 3000 square feet with
8' side walls.) If your system is this large, the cost of the SHCS gets
a little scary, at least the cost per square foot starts creeping up too
high. In such cases, you can trim down the size of the various package
elements - but be sure you use higher temperature inputs. For large
volume systems I recommend putting in a large diameter inlet duct that is
accessing the hottest possible free air source. And paint it flat black if
it's in the sun.
No,
using heavily perforated tubing, and 4" size, the soil microbes
influence the tubing zone so intimately that 'bad' mold doesn't have
a chance to get established, there is too much diversity for any one variety to
take over. Circulating organically laden air might be
different though - so air from composting and animal housing might be a
problem - it could provide the nutrient to get something going that is
unusual in normal soil strata. I've never seen problematic mold in
normal scenarios.
Composting in greenhouses is far too tricky to manage for the
inexperienced. Stay away unless YOU understand the process - ammonia
and methane in a greenhouse will quickly destroy the plants, building,
equipment and environment not to mention the soil if a SHCS is in
operation. Great in theory, but one of those "buyer beware"
situations...
You
could use the top layer of tubing as a conduit to run some drip lines
in. But flood irrigation through the entire system wouldn't work - too many perforations.
You
can do the numbers yourself. If designed accurately, you can expect to
raise the soil temperature to 65-75F by the end of the summer. That is
the soil temperature of all the soil in the greenhouse to a depth of 3
feet!! You can expect to keep it there for at least 3 months after the
summer season before it begins to discharge seriously. That represents
an enormous influence on the zone above it. For a 30' by 20' greenhouse
I believe that is in the neighbourhood of 75 tons of soil and
represents several million BTU's of heat. How this all pans out for
season extension is a guess, but I assure you, it will extend your
season!! For Zone 4, we can grow in simple hoop houses for 8 months of
the year using just a SHCS. Adding insulated north walls, double skins,
propane CO2 generators and tighter building envelope we can grow well for 12
months.
I
normally recommend thermostatically controlled CO2 generators for
supplemental heat. They are not vented, adding humidity and extra heat
as well as the CO2 the plants will need when growing in a closed winter
space. And do install a Carbon Monoxide meter and Oxygen sensor with a digital ppm
readout and alarm to be safe!
Two forums are currently available.
- Go here for General
Permaculture discussion relating to all matters connected habitat design
and optimization including SHCS systems and solar heated
greenhouses.
- Go here for
specific SHCS discussion involving some of my clients
- Go here for a fee schedule for my
services
- Systems costs are outlined with the free
online SHCS System Calculator
- Basic 2006 ballpark for the hardware costs of a SHCS - $200 per 1500 per square foot of greenhouse
space PLUS fifty cents per square foot.
|